Supplies
Level Indicators
GESCO provides different types of level indicators as per your needs listed below:
- Electromagnetic Flow Meter
- Digital Magnetic Flow Meter
- Water Flow Meter
- Digital Electromagnetic Flow meter
- Cement Slurry Meter
- Battery Operated Digital Flow Meter
- Hot Water Flow Meter
- Fuel Tank Level Indicators
- Water Level Indicators
- Liquid Flow Sensor
- Side Mounted Level Switch
- Side Mounted Level Indicator
Level Indicators Technical Specifications, Features, Design and Performance
Material of Construction: MS, SS 304, SS 316 & SS 316L
Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
Process Pressure: Max. 25 kg/cm2
Process Temperature: Max. 150C
Flow Tube Material: SS 316
End Connection: Flange/Wafer
Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF>
Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy: ± 1%
FSD Optional: ±0.5% FSD
Repeatability: 0.3%
Display: 2 Line Alfa Numeric LCD
Display Version: Integral /Remote
Display Unit: Standard Unit in M3, Litr
Power Supply: 230 VAC, 110 VAC & 24 VDC
Output: Std. 4 – 20 mA
Installation: Inline Flange Type
Material of Construction: MS, SS 304, SS 316 & SS 316L
Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
Process Pressure: Max. 25 kg/cm2
Process Temperature: Max. 150C
Flow Tube Material: SS 316
End Connection: Flange/Wafer
Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF
Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy: ± 1% FSD Optional: ±0.5% FSD
Repeatability: 0.3%
Display: 2 Line Alfa Numeric LCD
Display Version: Integral /Remote
Output: Std. 4 – 20 mA
Protection Class for Sensor: IP 65
Protection Class for Transmitter: IP 65
Cable Length for Remote: 10 meters
Installation: Inline Flange Type
Material of Construction: MS, SS 304, SS 316 & SS 316L
Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
Process Pressure: Max. 25 kg/cm2
Process Temperature: Max. 150C
Flow Tube Material: SS 316
End Connection: Flange/Wafer
Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF
Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy: ± 1%
FSD Optional: ±0.5% FSD
Power Supply: 230 VAC, 110 VAC & 24 VDC
Output: Std. 4 – 20 mA
Protection Class for Sensor: IP 65
Protection Class for Transmitter: IP 65
Cable Length for Remote: 10 meters
Installation: Inline Flange Type
Material of Construction: MS, SS 304, SS 316 SS 316L
Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, Tantalum
Process Pressure: Max. 25 kg/cm2
Process Temperature: Max. 150C
Flow Tube Material: SS 316
End Connection: Flange/Wafer
Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF
Measuring Range: 0.5 m/sec for Minimum 5m/sec for Maximum
Accuracy: ± 1% FSD Optional: ±0.5% FSD
Repeatability: 0.3% Display: 2 Line Alfa Numeric LCD Display Version: Integral /Remote
Display Unit: Standard Unit in M3, Litre
Power Supply: 230 VAC, 110 VAC 24 VDC
Output: Std. 4 – 20 mA
Protection Class for Sensor: IP 65
Protection Class for Transmitter: IP 65
Cable Length for Remote: 10 meters
Installation: Inline Flange Type
Material of Construction: MS, SS 304, SS 316 & SS 316L
Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
Process Pressure: Max. 25 kg/cm2
Process Temperature: Max. 150C
Flow Tube Material: SS 316
End Connection: Flange/Wafer
Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF
Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy: ± 1% FSD Optional: ±0.5% FSD
Repeatability: 0.3% Display: 2 Line Alfa Numeric LCD Display Version: Integral /Remote
Display Unit: Standard Unit in M3, Litre Power Supply: 230 VAC, 110 VAC & 24 VDC
Output: Std. 4 – 20 mA
Protection Class for Sensor: IP 65
Protection Class for Transmitter: IP 65
Cable Length for Remote: 10 meters
Installation: Inline Flange Type
steel Lining: PTFE / Rubber
Electrode: stainless steel, titanium, tantalum, etc.
Nominal diameter of the pipeline, DN: 10 TO 1000 mm Accuracy: 0.25% /0.5%
Repeatability: 0.2
Maximum pipeline pressure: 25 bar / 40 bar on request Minimum conductivity: 1 µS/cm
Fluid temperature range : -10 to 100/150 °С Ambient temperature range : -25 to 70 °С Protection : IP-67/ EX/EX
Power supply Battery operated : 24v dc, : 230 v ac
Outputs: 4-20 mA analog output; Pulse outputs , RS-485 interface , HIGH & Low alarm output
Material of Construction: MS, SS 304, SS 316 & SS 316L
Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
Process Pressure: Max. 25 kg/cm2
Process Temperature: Max. 150C
Flow Tube Material: SS 316
End Connection: Flange/Wafer
Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF
Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy: ± 1%
FSD Optional: ±0.5% FSD
Repeatability: 0.3%
Display: 2 Line Alfa Numeric LCD
Display Version: Integral /Remote
Display Unit: Standard Unit in M3, Litre
Power Supply: 230 VAC, 110 VAC & 24 VDC
Output: Std. 4 – 20 mA
Protection Class for Sensor: IP 65
Float Inside the tank raises and dales with the level of fluid this makes the pointer move one the scale indicating level inside the tank. In this level gauge, when tank is full the pointer is at bottom position on board and when tank is empty, the pointer will be at top position.
Float S.S.316 / S.S.304 / Poly Propylene
Float Wire & Float Guide Wire S.S.316 / Poly Propylene
Pulley & Pulley Pin M.S. / S.S.304
Pulley Housing Aluminium / S.S.304 / S.S.316 die Cast Weather Proof Enclosure of Weather Proof
Board (Scale) Aluminium with Powder Coated having 150 mm Width & White Background & Black writing at every 10CM and Red Marking at Every Meter
Pointer M.S / SS.304 with PP Roller for Frictionless Sliding On Board
Available from 1 Meter to 30 Meter
Float Inside the tank raises and deals with the level of fluid this makes the pointer move on the scale indicating level inside the tank. In this level gauge, when tank is full the pointer is at bottom position on board and when tank is empty, the pointer will be at top position.
Simple, low cost and reliable level gauge. Wetted parts available in SS304 / SS316 / PP
Suitable for installation on "tank in service”. Indicator rolls on the gauge board with the help of PVC Rollers
Can be used for the applications with volatile liquid or inert gas blanketing by using liquid seal assembly
Large numerals visible from a distance easily reable from a distance
Simple installation and commissioning. No maintenance required
Materials of Construction Float S.S.316 / S.S.304 / Polypropylene
Float Wire & Float Guide Wire S.S.316 / Polypropylene
Pulley & Pulley Pin M.S. / S.S.304
Pulley Housing Aluminum / S.S.304 / S.S.316 die Cast Weather Proof Enclosure of Weather Proof
Board (Scale) Aluminum with Powder Coated having 150 mm Width & White Back Ground & Black writing at every 10CM and Red Marking at Every Meter
Anchor Plate M.S / S.S.304 / S.S.316
Scale Bracket (T) M.S. / S.S.304
Pointer M.S / S.S.304 with PP Roller for Frictionless Sliding On Board
Available From 1 Meters to 30 Meters
Simplified piping and reduced space requirements
Permanent magnetic link between metering float and motion position transmitter
Precision swaged metering tube
Heavy duty welded float and guide construction
Guide cartridges easily removable for cleaning
Provide with Electrical transmitter, flow indicator OR alarm
Scale length: 180 degree Angular
Pressure Ratings: 40 Bar
Temperature Ratings: - 20º C to 250º C
Enclosure: IP 55 OR IP 65 on request
Tube: 316SS, 316LSS, 304SS, Hastelloy ‘C”, Titanium
Float: 316SS, 316LSS, 304SS, Hastelloy ‘C”, Titanium
Indicator Box: ABS, Cast Al
SS End Fitting: 316SS, 316LSS, 304SS, Hastelloy ‘C”, Titanium
Mainly used for measuring rated flow of liquid and gases. Available in C.S, SS-304, SS-316 Poly Propelene.P.T.F.E. Lined.Flanged, Screwed or Hose connections. Available from 15 NB to 100 NB pipe size and ranges between 30 to 20,000 LPH of water at ambient temperature. Linear scale having accuracy of 2% FSD.High & Low flow switches.
A magnetized float moves with level in external chamber (cage) which is coupled with the tank
Magnetically coupled follower capsule or roller or ball indicates the liquid level externally
Reliable for aggressive, combustible, toxic, high pressure and high temperature up to 150 degree liquid storage tanks.Suitable for Ethylene, Benzene, Toluene, Alcohols, Acids, Alkalies, Liquefied gases like NH3,Cl2,LPG,PCl3,so and poisonous/toxic liquid like DMA, TEA etc.
High and low level switching can be offered in weather/flame proof housing on request
Magnetic Level Transmitter can be provided on request
Suitable for fitting into tanks or process vessels for controlling liquid levels for preventing tank overflow
To control dry pump running/ Solenoid Valve.Minimum 50 NB flanged to any size.Weather proof (IP-65) or Flame proof to IIA, IIB as per CMRS, Dhanbad approved
External cage on request.High Temperature (Max 350 degree) on request
Made from Aluminium Bar Stock.Switch: Micro Switch.
5Amp@240V ACSwitching differential: Fixed 25 ±2mm.
Die Cast Aluminium, Weather Proof IP65 (Enclosure) (IS-2147) OR Flame Proof to IIA, IIB (IS-2148 CMRS Dhanbad Approved)Load/Insution: Resistive/150 Mega ohms at 500 VDCOperating Pressure: 20 Kg/Cm2Operating Temp: Maxi. 400º C.Cable Entry: ½”NPT (F) OR ¾“ET (F).
Indicator system is consists of bi-colour rollers equipped with magnets mounted on rail inside the housing. As the level starts rising or falling magnetic float also travels with liquid level in non-magnetic chamber. The magnetic interaction between magnets in float and bi-colour rollers causes each roller to rotate 180o. We are providing high & low Level Switch adjustable.
Indicator system consists of bi-colour capsule which moves in glass tube inside the housing. As the level stars rising or falling magnetic float also travels with liquid level in non-magnetic chamber. The magnetic interaction between magnets in float and capsule causes capsule to travel along with magnetic float. We are providing high & low Level Switch adjustable.
FLOWTECH Make Side Mounted Magnetic Level Indicator:
A magnetized float moves with level in external chamber (cage) which is coupled with the tankMagnetically coupled follower capsule or roller or ball indicates the liquid level externally
Reliable for aggressive, combustible, toxic, high pressure and high temperature up to 150-degree liquid storage tanks
Suitable for Ethylene, Benzene, Toluene, Alcohols, Acids, Alkalies, Liquefied gases like NH3,Cl2,LPG,PCl3,so and poisonous/toxic liquid like DMA, TEA etc
High and low level switching can be offered in weather/flame proof housing on request
Magnetic Level Transmitter can be provided on request
Gallery
Click to browse different Level Indicators.
(Scroll right to see images and click magnifying glass to veiw full mode)